Problem 1:Gear pump does not absorb oil after starting

Solutin:

  1. Check the oil tank level to ensure it reaches the gear pump’s suction port.
  2. Ensure the suction line is free from blockages or leaks and that all connections are tight.
  3. Check for air in the gear pump and bleed the system if necessary.
  4. Ensure the gear pump is rotating in the correct direction, adjusting according to the arrow marked on the pump body.

Problem 2: Loud noise during gear pump operation

Solution :

  1. Check that the gear pump is securely mounted and that there are no loose components.
  2. Check if the gear clearance is too large, and adjust or replace worn gears as needed.
  3. Ensure the gear pump is well-lubricated and regularly add the appropriate amount of lubricant.
  4. Inspect the suction line for air leaks or blockages to ensure smooth suction.

Problem 3: Insufficient discharge pressure from the gear pump

Solution :

  1. Inspect the discharge line for blockages or leaks to ensure it is clear.
  2. Check for internal wear in the gear pump and replace worn parts as necessary.
  3. Ensure the gear pump’s speed and power meet the required specifications, adjusting motor speed or replacing the motor as needed.
  4. Inspect the hydraulic system’s pressure control valve to ensure it is functioning correctly, adjusting or replacing it if necessary.

Problem 4: Severe leakage in the gear pump

Solution :

  1. Check all seals for integrity and replace damaged seals as needed.
  2. Ensure that the pump housing and piping connections are tight, securing all connections.
  3. Inspect the gear pump shaft seal for damage and replace it if necessary.
  4. Ensure the pump body has no cracks or other damage, repairing or replacing the pump if required.

Problem 5: Gear pump overheating during operation

Solution :

  1. Check the temperature and viscosity of the hydraulic fluid to ensure the use of suitable hydraulic oil.
  2. Ensure the oil tank and cooling system are functioning properly, cleaning or replacing the cooler if necessary.
  3. Inspect the gear pump internals for contaminants or blockages, regularly cleaning the pump of debris.
  4. Ensure the gear pump operates within its rated conditions and avoid prolonged operation under excessive load.
Le précédent : Le suivant :

Recommandations associées

  • Plusieurs raisons de choisir des pompes à engrenages en fonte

    2819

    Les pompes hydrauliques jouent un rôle essentiel dans les domaines industriel et mécanique, et les pompes à engrenages sont l'un des types classiques. En tant que composant central du système hydraulique, la pompe à engrenages est largement utilisée dans l'agriculture, les machines de construction, les automates industriels...

    Voir les détails
  • Comment renforcer l'entretien et la maintenance des pompes

    3089

    1.sélectionner le bon type de pompe 2.vérifier régulièrement l'état de fonctionnement de la pompe 3.assurer une dissipation efficace de la chaleur et une gestion thermique de la pompe 4.remplacer régulièrement l'huile hydraulique et le filtre 5.assurer une étanchéité à haute pression et une protection contre les fuites 6.s'appuyer sur la b...

    Voir les détails
  • Réparation et entretien des machines hydrauliques

    2911

    Afin de maintenir les bonnes performances de la pompe hydraulique, il est nécessaire d'inspecter et de remplacer régulièrement les pièces vulnérables et de veiller à l'utilisation d'une huile hydraulique et d'éléments filtrants de haute qualité. En outre, il convient de prêter attention à...

    Voir les détails
Cliquez sur Annuler pour répondre
    Développez plus !