{"id":7153,"date":"2024-10-28T16:55:00","date_gmt":"2024-10-28T08:55:00","guid":{"rendered":"https:\/\/www.rchchydraulics.com\/?p=7153"},"modified":"2025-06-05T18:21:59","modified_gmt":"2025-06-05T10:21:59","slug":"how-to-improve-the-life-of-gear-pump-maintenance-skills-and-troubleshooting","status":"publish","type":"post","link":"https:\/\/www.rchchydraulics.com\/fr\/how-to-improve-the-life-of-gear-pump-maintenance-skills-and-troubleshooting.html","title":{"rendered":"Comment am\u00e9liorer la dur\u00e9e de vie d'une pompe \u00e0 engrenages ? Comp\u00e9tences en mati\u00e8re d'entretien et de d\u00e9pannage"},"content":{"rendered":"<ol class=\"wp-block-list\">\n<li>Improve gear pump life maintenance skills<br>\u00b7 Replace hydraulic oil regularly<br>It is important to ensure the cleanliness of the hydraulic fluid. The pollutants in the hydraulic oil will accelerate the wear of the gear pump, it is recommended to check the oil quality regularly and replace it in time to avoid the oil containing impurities into the system.<\/li>\n<\/ol>\n\n\n\n<p>\u00b7 Ensure that the oil temperature is within the appropriate range<br>Gear pump operating temperature is usually 20-60 \u00b0 C, beyond this temperature range will lead to oil viscosity changes and internal component losses increased. A cooling device can be installed to control the oil temperature to ensure that the pump works at the optimal temperature.<\/p>\n\n\n\n<p>\u00b7 Avoid dry grinding<br>Before starting the gear pump, fill the pump chamber with oil to prevent the gear from running under dry grinding conditions. In addition, when the equipment is started again after a long shutdown, check the lubrication condition first.<\/p>\n\n\n\n<p>\u00b7 Clean the filter screen and filter element regularly<br>The filter screen and filter element in the hydraulic system will accumulate impurities, and should be cleaned and replaced regularly to ensure the purity of the oil.<\/p>\n\n\n\n<p>\u00b7 Correct installation and alignment<br>Gear pump installation should be maintained level and ensure alignment. Alignment deviation will lead to unstable operation and affect the meshing accuracy and life of the gear.<\/p>\n\n\n\n<p>\u00b7 Avoid overload<br>Running under high pressure or high load conditions for a long time will increase the wear of the gear pump, and it should be avoided to exceed the rated working pressure and flow range of the pump to prevent early failure.<\/p>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li>Common troubleshooting and solutions<br>\u00b7 Excessive noise<\/li>\n<\/ol>\n\n\n\n<p>Reasons: the gear gap is too large, there are bubbles in the hydraulic oil or the oil viscosity is inappropriate.<br>Solution: Check whether there are bubbles in the oil, re-exhaust if necessary, or adjust the viscosity parameters of the oil.<\/p>\n\n\n\n<p>\u00b7 Insufficient or unstable pressure<br>Cause: insufficient oil, blockage of filter element, internal leakage.<br>Solution: Check the hydraulic oil level and supplement, replace the filter element, if there is leakage, check the wear of the seal and replace it in time.<\/p>\n\n\n\n<p>\u00b7 Oil temperature is too high<br>Cause: prolonged high load operation, insufficient tank capacity or poor cooling.<br>Solution: Check whether the cooling device is working properly, and increase the tank capacity or install an auxiliary cooling system if necessary.<\/p>\n\n\n\n<p>\u00b7 Traffic decline<br>Cause: gear and bearing wear serious, internal leakage increases.<br>Solution: Check gear meshing and bearing wear, replace wear parts if necessary, and detect leakage points.<\/p>\n\n\n\n<p>\u00b7 Difficulty in starting or pump stuck<br>Cause: oil viscosity is too high, gear damage or there is a foreign body in the pump chamber.<br>Solution: Choose the oil suitable for the ambient temperature, clean the foreign matter in the pump chamber, and regularly check the gear mesh.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00b7 Ensure that the oil temperature is within the appropriate rangeGear pump operating temperature is usually 20-60 \u00b0 C, beyond this temperature range will lead to oil viscosity changes and internal component losses increased. A cooling device can be installed to control the oil temperature to ensure that the pump works at the optimal temperature. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7154,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[7],"tags":[60,49,50,53,48,51,54],"class_list":["post-7153","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-heavy-duty-hydraulic-gear-pump","tag-hydraulic-oil-pump","tag-hydraulic-pump","tag-hydraulic-pump-factory","tag-jcb","tag-parker","tag-pgp"],"metadata":{"_edit_lock":["1749118919:1"],"_thumbnail_id":["7154"],"_edit_last":["1"],"catce":["sidebar-widgets4"],"wp_statistics_words_count":["444"],"views":["2217"],"themepark_seo_title":["How to improve the life of gear pump? Maintenance skills and troubleshooting"],"themepark_seo_description":["How to improve the life of gear pump? Maintenance skills and troubleshooting"],"themepark_seo_keyword":["heavy duty hydraulic gear pump,hydraulic oil pump,Hydraulic pump,Hydraulic pump factory,JCB,Parker"]},"medium_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/10\/WechatIMG80-300x169.jpeg","thumbnail_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/10\/WechatIMG80-150x150.jpeg","full_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/10\/WechatIMG80.jpeg","_links":{"self":[{"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/posts\/7153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/comments?post=7153"}],"version-history":[{"count":1,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/posts\/7153\/revisions"}],"predecessor-version":[{"id":7155,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/posts\/7153\/revisions\/7155"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/media\/7154"}],"wp:attachment":[{"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/media?parent=7153"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/categories?post=7153"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/fr\/wp-json\/wp\/v2\/tags?post=7153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}