{"id":7031,"date":"2024-09-20T16:55:00","date_gmt":"2024-09-20T08:55:00","guid":{"rendered":"https:\/\/www.rchchydraulics.com\/?p=7031"},"modified":"2024-09-18T15:30:49","modified_gmt":"2024-09-18T07:30:49","slug":"gear-pump-common-faults-and-maintenance","status":"publish","type":"post","link":"https:\/\/www.rchchydraulics.com\/es\/gear-pump-common-faults-and-maintenance.html","title":{"rendered":"Aver\u00edas comunes y mantenimiento de la bomba de engranajes"},"content":{"rendered":"<ol class=\"wp-block-list\">\n<li>Excessive noise<br>The cause of the fault:<br>\u00b7 The oil contains air<br>\u00b7 gear pump internal wear serious<br>\u00b7 The oil suction port is blocked<br>Maintenance method:<br>\u00b7 Check tank level to ensure sufficient hydraulic oil and remove air.<br>\u00b7 Clean or replace the oil filter and check the suction line.<br>\u00b7 Check gear wear and replace gear if necessary.<\/li>\n\n\n\n<li>Lack of stress<br>The cause of the fault:<br>\u00b7 gear pump internal leakage is serious, resulting in low pumping efficiency.<br>\u00b7 Control valve failure or damage, pressure regulation is unstable.<br>\u00b7 Suction pipe leakage, resulting in insufficient oil absorption.<br>Maintenance method:<br>\u00b7 Check gear and bearings for wear and repair or replace seals.<br>\u00b7 Check the working condition of the control valve and repair or replace it if necessary.<br>\u00b7 Check the tightness of the suction line to ensure that no air enters.<\/li>\n\n\n\n<li>Traffic fluctuation<br>The cause of the fault:<br>\u00b7 gear pump quantification is inaccurate, resulting in unstable flow.<br>The pump body or bearing of the gear pump is severely worn, resulting in internal leakage.<br>Maintenance method:<br>\u00b7Check the metering mechanism of the pump and adjust or replace it.<br>\u00b7Check pump body for wear and repair or replace related parts.<\/li>\n\n\n\n<li>The pump temperature is too high<br>The cause of the fault:<br>\u00b7 The oil viscosity is too high or too low, resulting in increased friction resistance of the gear pump.<br>\u00b7 The oil circuit is blocked, and the oil cannot circulate smoothly, resulting in overheating of the pump body.<br>\u00b7 Heat dissipation device failure in the hydraulic system, can not effectively heat dissipation.<br>Maintenance method:<br>\u00b7 Select the hydraulic oil suitable for the temperature environment to ensure that the oil viscosity is appropriate.<br>\u00b7 Check the oil circuit and clear the clogged part.<br>\u00b7 Check the working status of the heat dissipation system, and repair or replace the heat dissipation device if necessary.<\/li>\n\n\n\n<li>Internal leaks<br>The cause of the fault:<br>\u00b7 Gear, bearings, seals and other wear, resulting in serious internal leakage.<br>\u00b7 gear pump assembly accuracy is not enough, the seal is not strict.<br>Maintenance method:<br>\u00b7 Replace worn gears, bearings, seals and other parts.<br>\u00b7 Adjust the assembly accuracy to ensure that the clearance between the components meets the requirements.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":7037,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[7,1],"tags":[],"class_list":["post-7031","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-uncategorized"],"metadata":{"_edit_lock":["1726735309:1"],"_edit_last":["1"],"catce":["sidebar-widgets4"],"views":["2861"],"_thumbnail_id":["7037"],"themepark_seo_description":["1.Excessive noise 2.Lack of stress 3.Traffic fluctuation 4.The pump temperature is too high 5.Internal leaks"],"themepark_seo_keyword":["Controlvalve  parker  jcb CASAPPA  PGP620 PGP640 PGM620 PGM640 Forkliftpump doublepump Bombahidr\u00e1ulica hydraulicvalve hydraulicpump  hydraulicpump Hidrolik Pompehydraulique Gearpump #Constantdisplacementpump Hightension Lowpressure Flowcontrol Pressurecontrol"],"wp_statistics_words_count":["333"],"_trp_automatically_translated_slug_ru_RU":["\u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435-\u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438-\u0438-\u0442\u0435"]},"medium_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/09\/WechatIMG39-300x169.jpg","thumbnail_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/09\/WechatIMG39-150x150.jpg","full_url":"https:\/\/www.rchchydraulics.com\/wp-content\/uploads\/2024\/09\/WechatIMG39.jpg","_links":{"self":[{"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/posts\/7031","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/comments?post=7031"}],"version-history":[{"count":3,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/posts\/7031\/revisions"}],"predecessor-version":[{"id":7038,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/posts\/7031\/revisions\/7038"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/media\/7037"}],"wp:attachment":[{"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/media?parent=7031"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/categories?post=7031"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rchchydraulics.com\/es\/wp-json\/wp\/v2\/tags?post=7031"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}